Posted date: 23-Oct-2025 3:26:19 PM VN
Some amends and supplements of the

Circular No. 16/2025/TT-BCT⛔ - New regulations on registration to participate in the electricity market from February 1, 2025

within:
  • Circular No. 36/2025/TT-BCT⛔ - Amendments to regulations on operation of the electricity wholesale market
  • Effected from: 03-Jun-2025
    New additions
    ◦ Article 3, Clause 1, Point b (amended Clause 2, Article 3 of Circular 16): Add a clear definition of "The amount of electricity output operated and mobilized corresponds to the maximum level according to the gas supply capacity..." in the concept of "undertaking".
    ◦ Article 3, Clause 2 (supplement Clause 19a, Article 3 of Circular 16): Add a specific definition of "Gas-fired thermal power plants are required to make maximum use of gas fuel sources", along with citations to relevant Decrees.
    ◦ Article 132, Clause 4 (supplement Clause 4, Article 132 of Circular 16): Clearly stipulates the responsibility of Vietnam Electricity Group or the electricity wholesaler in providing data on consumption to the Power System Operator and the electricity market.
    ◦ Article 132, Clause 5 (supplement Clause 5 Article 132 of Circular 16): Clearly stipulates the responsibilities of Power Generation Units and Fuel Supply Units in providing data on gas supply capacity and fuel requirements of Thermal Power Plants that are required to use maximum gas fuel sources for the Power System Operator and the electricity market.
    ◦ Article 133, Clause 4a (supplement Clause 4a, Article 133 of Circular 16): Specific regulations on the roadmap and mobilization methods for hydropower plants operating in coordination with multi-purpose strategic hydropower plants during the period of not directly participating in the electricity market (before June 1, 2026).
    ◦ Article 1, Clause 22: Add Appendix VI to Circular No. 16/2025/TT-BCT
    ◦ Article 1, Clause 17 (supplement Clause 4a, Article 133 of Circular 16): During the period of not directly participating in the electricity market, these hydropower plants are mobilized as power plants indirectly participating in the electricity market.
    ### Changes
    FocusOldNew
    Scope of adjustment of hydropower plantsb) Power plants with a designed capacity of 10 MW or more whose power purchase contracts based on avoided costs expire, including cascade (for hydropower) and power plants using other renewable energy... Article 4, clause 1b) Power plants with an installed capacity of 10 MW or more whose power purchase contracts based on avoided costs expire, including cascade hydropower plants and power plants using other renewable energy... Article 4, clause 1
    Type of BOT factoryThis phrase is not included in the amendment Article 4, Clause 1"Design capacity" is changed to "Installed capacity" Article 4, Clause 1
    BOT plant typeThermal power plants are required to make maximum use of gas fuel sources and are allowed by competent state agencies to indirectly participate in the electricity market; Article 4, paragraph 3Gas-fired thermal power plants are required to make maximum use of gas fuel sources Article 4, paragraph 3
    Scope of application of Article 11...not completing registration to participate in the electricity market, power plants without a Power Purchase Agreement... Article 11, Clause 1...not completing registration to participate in the electricity market (except for hydropower plants that coordinate operations with multi-purpose strategic hydropower plants as prescribed in Clause 4a, Article 133 of this Circular), power plants without a Power Purchase Agreement... Article 11, Clause 1
    Order of mobilization when overloaded, surplus sourcea) Reduce the generating capacity of thermal power plants with variable costs in order from high to low Article 18, clause 3a) Reduce the generating capacity of thermal power plants with variable costs in order from high to low, except for thermal power plants of gas-fired thermal power plants that are required to make maximum use of gas fuel sources Article 18, clause 3
    Order of mobilization in case of overload or excess powere) Reducing part or all of the wind power plant, grid-connected solar power plant (except for power plants under Point h, Clause 3 of this Article);... Article 18, Clause 3e) Reducing part or all of the wind power plant, grid-connected solar power plant (except for power plants under Point k, Clause 3 of this Article);... Article 18, Clause 3
    Order of mobilization when overloaded, excess sourceAdd more linesg) Reduce the generation capacity of thermal power units of gas-fired thermal power plants that are required to use gas fuel to the maximum; h) Stop thermal power units of gas-fired thermal power plants that are required to use gas fuel to the maximum with variable costs in order from highest to lowest; Article 18, Clause 3
    Order of mobilization in case of overload or excess sourceProportional reduction4. For generators of power plants belonging to the same group at points e, g, i and k, Clause 3 of this Article, the reduction of generating capacity is carried out according to the principle of evenly distributing the capacity to be reduced according to the ratio of rated capacity, available capacity, announced capacity or forecast capacity (depending on the type of power source and dispatch method), regardless of price criteria Article 18, Clause 4
    Constraints in power system operationGuarantee constraintsConstraints on underwriting Article 19, Clause 2
    Amendment and supplement to Article 32- Solutions to ensure stable, safe and reliable operation of the power system- Solutions to ensure stable, safe and reliable operation of the power system. Water value and optimal water level of cascade hydropower plants and hydropower plants with reservoirs regulating for 2 or more days per week in the coming month; Article 42, Clause 1
    ### Abolished or expired
    ◦ Article 2, Clause 1: Abolish point c, Clause 1, Article 17 of Circular 16.
    ◦ Article 2, Clause 2: Abolish Clause 15, Article 54 of Circular 16.
    ◦ Article 2, Clause 3: Abolish Clause 15, Article 60 of Circular 16.
    ◦ Article 2, Clause 4: Abolish Clause 9, Article 13, Appendix II issued with Circular 16.
    ### General comments on the impact of the difference
    ◦ Focus on Gas-fired Power Plants: The amendments and supplements mainly focus on clarifying and prioritizing gas-fired power plants that are bound to make maximum use of gas fuel sources. This demonstrates efforts to ensure the utilization of domestic gas resources and optimize the operation of gas-fired power plants.
    ◦ Specifying and detailing regulations: Circular 36/2025/TT-BCT adds more detailed definitions and regulations, making the implementation and supervision of the electricity market clearer and more effective.
    ◦ Priority of power supply and system stability: Amendments to the order of power mobilization in case of overload and excess power show high priority for ensuring stable and reliable power supply for the system, especially in the context of increasing participation of renewable energy sources.
    ◦ Impact on market operations: These changes may affect market electricity prices and payments for power plants, especially gas-fired power plants. Relevant entities need to be aware of the new regulations to ensure compliance and optimize their operations in the electricity market.
    ◦ More flexibility in dispatching Modifications from "design capacity" to "installed capacity" or the requirement to sign additional contract appendices will help the operating unit operate more easily by closely monitoring the actual electrical equipment.
    Hope this analysis provides you with insight and useful information!